A Dutch cybersecurity researcher claims he found six zero-day vulnerabilities in Danfoss refrigeration controller firmware in under an hour; the CCB warned that the flaws could let attackers take control without credentials, potentially retain access after resets or disable controllers altogether.
Carlo Meijer of cyber consultancy Midnight Blue examined the latest AK-SM800A firmware, version 5.3.2, and said he found five cases where he could trigger a segfault by checking random places where the unsafe function strcpy() is used, given the vendor's "extremely liberal" use of it, and a sixth memory corruption flaw in the session-control layer.
Meijer noted that the exploited application runs as root and that the controllers lack standard exploit mitigations such as stack canaries and position-independent executables. "These mechanisms have been staples of memory corruption defenses for decades and enabling these features... requires no engineering work at all," he said. "It is simply a matter of setting the right compiler flag."
The Centre for Cybersecurity Belgium (CCB) has warned that the flaws could let attackers take control without credentials, potentially retain access after resets, or disable controllers altogether. Both Meijer and the CCB urged operators to remove the controllers' direct internet exposure immediately; Meijer recommended against spending resources on piecemeal patching.
"This is insufficient and asset owners need to remove internet exposure as soon as possible," said Meijer, referring to Danfoss's advice following recent attacks on European supermarkets and blood banks. The CCB also recommended applying patches when they become available.
Meijer also considered the feasibility of attackers maintaining access after a reset, as seen with implants such as Saltwater and Firestarter, because the controllers do not use their processor's secure boot features. "In such a scenario, an attacker could either retain remote access or leave a time-triggered payload for a 2nd (or 3rd...) strike – increasing damage by spoiling new batches of food," he said. He added that attackers could wipe flash memory or push a malformed firmware update to brick the controllers, requiring costly replacement similar to tactics used in the December 2025 attack on the Polish electric grid.
The Register asked Danfoss to respond to the findings, but it did not reply.
Analysis
Why This Matters
- The vulnerabilities affect refrigeration controllers used widely in supermarkets, blood banks, and food supply chains, posing direct risks to public health and food safety.
- The flaws are trivial to exploit and the devices lack decades-old memory corruption defenses, making them an easy target for attackers.
- The researcher's assessment suggests that patching alone is insufficient and that fundamental architectural changes, such as removing internet exposure, are needed.
Background
Danfoss is a Danish industrial controls manufacturer whose refrigeration controllers are deployed globally. Recent attacks on European supermarkets and blood banks have been linked to similar controller vulnerabilities. The AK-SM800A firmware version 5.3.2 was last updated within the past few months, yet still lacks basic security features that became default in Ubuntu 17.10.
Key Perspectives
Carlo Meijer (security researcher): says the flaws enable remote code execution, root-level access, and potential persistence after resets; calls the vendor's security advice insufficient and urges immediate removal from the internet.
Centre for Cybersecurity Belgium: recommends removing direct internet exposure immediately and also applying patches when they become available.
What to Watch
- Whether Danfoss releases firmware patches and whether they add basic mitigations such as stack canaries.
- Whether any of these zero-days are exploited before operators remove internet exposure.
- The timeline for operators to disconnect or replace affected controllers, given cost and supply constraints.
Checked
12 claims in this story checked against 1 source: 12 supported.
Show each claim
- SupportedMeijer claims he found six Danfoss refrigeration-controller zero-days in under an hour.www.theregister.com - Articles: “A Dutch cybersecurity researcher claims he found six zero-days in Danfoss refrigeration controller firmware in under an hour”
- SupportedThe CCB warned the flaws could let attackers take control without credentials, retain access after resets or disable the controllers.www.theregister.com - Articles: “The Centre for Cybersecurity Belgium (CCB) warns that the flaws could let attackers take control without credentials, potentially retain access after resets, or disable controllers altogether.”
- SupportedMeijer examined AK-SM800A firmware version 5.3.2.www.theregister.com - Articles: “Carlo Meijer of cyber consultancy Midnight Blue examined the latest AK-SM800A firmware, version 5.3.2, manually”
- SupportedMeijer said he found five cases where he could trigger a segfault by checking random places where strcpy() is used.www.theregister.com - Articles: “He said that he went looking in random places where strcpy() is invoked, given the vendor's "extremely liberal use" of the function (which doesn't check whether the destination buffer is large enough), and swiftly found five cases in which he said he could trigger a segfault”
- SupportedMeijer found a memory-corruption flaw in the session-control layer.www.theregister.com - Articles: “But Meijer found a memory corruption flaw in that protective layer too.”
- SupportedThe exploited application runs as root.www.theregister.com - Articles: “Meijer added: "Also, the exploited application runs as root (because of course it does)."”
- SupportedMeijer said the controllers lack standard exploit mitigations, including stack canaries and position-independent executables.www.theregister.com - Articles: “Beyond the liberal use of strcpy(), Meijer criticized the absence of standard exploit mitigations, including stack canaries and position-independent executables.”
- SupportedMeijer said, “These mechanisms have been staples of memory corruption defenses for decades and enabling these features... requires no engineering work at all,” and, “It is simply a matter of setting the right compiler flag.”www.theregister.com - Articles: “"These mechanisms have been staples of memory corruption defenses for decades and enabling these features... requires no engineering work at all," he said. "It is simply a matter of setting the right compiler flag.”
- SupportedMeijer and the CCB urged operators to remove the controllers’ direct internet exposure; the CCB also recommended applying patches when available.www.theregister.com - Articles: “The CCB likewise urged operators to remove direct internet exposure immediately, but also recommended applying patches when they become available.”
- SupportedMeijer recommended against spending scarce security resources on piecemeal patching.www.theregister.com - Articles: “"We recommend against allocating scarce security resources to patching efforts and instead focus on reducing exposure."”
- SupportedMeijer said, “This is insufficient and asset owners need to remove internet exposure as soon as possible,” referring to Danfoss’s advice after attacks on European supermarkets and blood banks.www.theregister.com - Articles: “He said the vendor's advice following the attacks on European supermarkets and blood banks in recent weeks – rotating creds, applying patches, enabling strict session control – was insufficient given the flaws in the controllers' codebase. "This is insufficient and asset owners need to remove internet exposure as soon as possible," said Meijer.”
- SupportedMeijer said attackers could retain remote access after a reset or leave a time-triggered payload for a later strike that could spoil new food batches.www.theregister.com - Articles: “"In such a scenario, an attacker could either retain remote access or leave a time-triggered payload for a 2nd (or 3rd...) strike – increasing damage by spoiling new batches of food," said Meijer.”